  1. 23. Why will my GFCI breaker not set when first powered up? The most likely cause is it is wired incorrectly with the load neutral and pigtail neutral wired together inside the external GFCI. Please consult with a licensed electrician to perform the GFCI wiring inspection. GFCI Load Center Wiring 1. Groundings. All groundings should come straight ...
  2. 129. Support: GFCI Immediately trips. This is not an initial install. When a GFCI trips it means that electricity is coming into contact with water or shorting to ground. It is not safe to use the spa in this condition. In an installation that has been up and running for some time, this is generally, but not always a damaged heater element. We can issue you an ...
  3. 130. Support: On an initial installation of a motor why does the motor run momentarily then stop? Common causes of the issue explained: MIS-MATCHED VOLTAGE The voltage of the motor and the voltage of the motor circuit do not match. For example: the controller's motor circuit is set to 220V, and the primary motor is actually 110V. MIS-WIRE The voltage of power supplied to the ...