  1. 365. Support: Blower is tripping the GFCI (SpaGuts Brand). Typical cause of the blower tripping the GFCI is that the motor is shorted to ground. Either the blower motor went bad, or water got inside the blower. Here is information about the air blower: The air blower is to be connected on an air line. The blower needs to be protected from rain and ...
  2. 560. Support: GFCI tripping only after the system has been running for sometime. With the GFCI tripping only after the system has been running for sometime, the problem can be the heater, water leaking from the heater, water infiltration onto the circuit board or water infiltration on other components (pump, blower, etc), loose wire connections, overheat on the wires or ...
  3. 722. SUPPORT: GFCI breaker still tripping again after the system have been repaired You have reported that the control system is tripping the GFCI breaker again after it was repaired and running for not too long. Check through the following items again. 1) Heater Element - Disconnect both heater cables from the circuit board to see if it stops the GFCI from tripping 2) ...