Articles by tag "topside display"

Sort By:

Set Descending Direction
  1. 467. Support: Balboa topside displays “OH//HH” Balboa topside displays "OH" or "HH” *One of the Water Temp Sensors has detected 110°F (43.3°C) for the incoming Water Temperature and Spa Functions are Disabled. System will Auto Reset when Water Temp is below 108°F (42.2°C). Check for Extended Pump Operation or High Ambient ...
  2. 518. Support: Balboa topside displaying (Snb or Sb) The Sensor Connected to the "Sens.B" Connector on the System Board may have failed and Spa Functions are Disabled. Check and Test Sensor B, Cable, and Connector for Damage, Connection, and Operation. Check the following: 1. Make sure Both Temperature Sensors are Properly Mounted at the ...
  3. 525. Support: Balboa topside displaying Ice or Ic A Potential Freeze Condition has been Detected, and "Ic/Ice" in the System is being Prevented. 44°F (6.7°C) or Lower has been Detected at the Lowest Temp Sensor, or the Aux Freeze Switch has Closed, and All Pumps and Blower are Activated. All Pumps and Blower are ON for at least 4 Minutes ...