  1. 560. Support: GFCI tripping only after the system has been running for sometime. With the GFCI tripping only after the system has been running for sometime, the problem can be the heater, water leaking from the heater, water infiltration onto the circuit board or water infiltration on other components (pump, blower, etc), loose wire connections, overheat on the wires or ...
  2. 587. Support: Wiring information for the (15-350-2293) Spa-Flo 2.0HP 220V SD Waterway Pump, 342102A-0Z. Note that All pumps we sell have the wiring diagram on the motor. If you missed it, here is the wiring information for the (15-350-2293) Spa-Flo 2.0 HP, 220V, Side Discharge, Waterway Pump, 342102A-0Z. Motor P/N: 7-196012-03 (Customer to verify. If different, provide correct motor number for ...
  3. 595. Support: Pump stopped working on VS-Series Spa Pack You have contacted us regarding the pump on the VS Series spa pack has stopped working. Please check the following: - Are you able to run the pump on low and high speed? Or is it only running in one speed? If the pump still runs but with low water flow, respond to us for Air Bleeding Guide. ...
  4. 596. Support: New pump making vibrating or buzzing noises on low and/or high speed, but runs fine. You have reported that the new pump is making vibrating or buzzing noises on low and/or high speed, but runs fine. Please try holding down the pump motor while it's running. If the noise goes away, it means that the pump or the base that the pump is mounted on needs to be bolted or tighten ...
  5. 605. Support: GFCI breaker is now tripping off a Spa Circuit Board. If the GFCI breaker is now tripping off a Spa Circuit Board, perform the following to troubleshoot: - Try unplugging all the component cords. This includes the electrical Topside (if one is installed), pump(s), blower, ozone and light. Now try setting the GFCI again. - If the GFCI sets, ...
  6. 606. Support: Wiring information for the (15-350-2130) 48-Frame 1.5HP 110V CD Waterway Pump, 342061A-15 Note that All pumps we sell have the wiring diagram on the motor. If you missed it, here is the wiring information for the (15-350-2130) 48-Frame 1.5 HP, 110V, Center Discharge, Waterway Pump, 342061A-15. Motor P/N: C48AA70A79R (Customer to verify. If different, provide correct motor number ...
  7. 608. Support: Wiring information for the (15-350-2180) 48-Frame 2.0HP 220V SD Waterway Pump, 342102A-10. Note that All pumps we sell have the wiring diagram on the motor. If you missed it, here is the wiring information for the (15-350-2180) 48-Frame 2.0 HP, 220V, Side Discharge, Waterway Pump, 342102A-10. Cat BN51. Motor S/N: 09113J2, Model number 7-182477-02 (Customer to verify. If different, ...
  8. 609. Support: Replacement thermostat does not work You reported that the replacement thermostat does not activate (click) when the temp dial is turned up to max. - Make sure the air temperature is not at 104 degrees F or more. If so, that is why the replacement thermostat does not activate. The thermostat max temperature is 104 degrees F. The ...
  9. 623. Support: Location of Topside cable connection for the VS-Series Controllers Topside Cable Connection for the VS Series Controllers Connect the topside cable plug into J1 connector on the circuit board. The clip on the topside cable plug should snap in place to ensure a secure connection. The J2 connector is for a secondary topside panel, which can be purchased ...
  10. 629. Support: Flow Switch Installation for the CS-Series and M-Series Controllers with Lo-Flow Heaters. Flow Switch Installation Instructions for the CS Series and M Series Controllers with Low Flow Heaters. 1) Flow Switch Appearance: The Flow Switch for Low-Flo Systems is clear blue in color, and will look like a Tee Shape with barb fittings on each end, and with a cable coming out from the ...