Before Purchase Questions

Sort By:

Set Descending Direction
  1. 525. Support: Balboa topside displaying Ice or Ic A Potential Freeze Condition has been Detected, and "Ic/Ice" in the System is being Prevented. 44°F (6.7°C) or Lower has been Detected at the Lowest Temp Sensor, or the Aux Freeze Switch has Closed, and All Pumps and Blower are Activated. All Pumps and Blower are ON for at least 4 Minutes ...
  2. 526. Support: Balboa topside displaying ---F The Actual Water Temperature is "Unknown". Priming Mode has been Exited and the Pump has Not yet run for 1 or 2 Minutes (depending on Model) to Sample Actual Water Temperature. With the Heat Related Pump Running, wait at Least 2 Minutes for the Correct Actual Water Temperature to be Displayed.
  3. 527. Support: Balboa topside displaying St or Std The Spa is Operating in the "Standard" Heating Mode. Between Filter Cycles, the Water Temperature is Sampled every 30 Minutes. The Heater and Pump will Operate Any time the Thermostat Demands Heat. The Water Temperature is Always maintained within 1°F (.5°C) of Set Temperature. Other Heating ...
  4. 528. Support: Balboa topside displaying Ec or Ecn If the Ecn or Ec Message is Alternating with the Water Temperature on the Display, the Spa is Operating in the Economy Heating Mode. If the Ecn or Ec Message is ON Solid (Not Flashing) on the Display, the Spa is Operating in the Economy Heating Mode, but there is No current water temperature ...
  5. 529. Support: Balboa topside displaying SL or SLP If the "SLP" or "SL" Message is Alternating with the Water Temperature on the Topside Display, the Spa is Operating in the "Sleep Heating Mode". This is NOT an error message. Note that a Sleep Heating Mode will drop the water temperature 20 degrees below the set temperature. Please see the ...
  6. 530. Support: Balboa Controller VS500Z and VS501Z Mode Settings for Standard, Economy and Sleep. Mode is changed by pressing the Temp or Set button, and then pressing the Light button. If there are UP and DOWN buttons, use the UP button. Do not press the buttons at the same time. It's one button, release, and then the other button. Standard Mode (St) is programmed to maintain the ...
  7. 531. Support: Balboa VS500Z and VS501Z Filter cycle settings The first filter cycle begins 6 minutes after the spa is energized. The second filter cycle begins 12 hours later. Filter duration is programmable for 2, 4, 6, 8 hours or for continuous filtration (indicated by Fc). The default filter time is 2 hours.To program, press Temp or Set, then Jets. ...
  8. 532. Support: Balboa Controller VS510SZ Mode Settings for Standard, Economy and Sleep. Mode is change by pressing the warm or cool button, and then pressing the mode button. Do not press the buttons at the same time. It's one button, release, and then the other button. Standard Mode (Std): is programmed to maintain the desired temperature. Note: that the last measure spa ...
  9. 533. Support: VS "SZ" Series controller Filter cycles settings Preset Filter Cycles (Filtration Cycle) for the VS Series The first preset filter cycle begins 6 minutes after the spa is energized (at first power up). If you want the filter cycle to start at 8pm daily, power up the spa at that time. The second preset filter cycle begins 12 hours later (If ...
  10. 539. Support: Bath Heater not working Please check the following: 1) The jetted bath tub needs to be filled up to the required level with hot water (check with the hot tub manufacturer for the appropriate water level). The bath heater is meant to maintain the hot water in the bath tub. It is not meant to heat the water from scratch ...