  1. 612. Support: Temperature reading in Fahrenheit or Celsius on a Balboa 54115 Circuit Board, 54114 Balboa System Make sure to turn off the power to the spa when performing the following configuration: Directly on the Balboa 54115 Circuit Board, there is a jumper J32. Move J32 jumper to hold onto ONLY one pin to read Fahrenheit. If the J32 jumper is holding both pins, it will allow the topside panel to ...
  2. 617. How do I exchange a SpaGuts pump for a different pump? Exchanging a recently ordered pump for a different pump can be done. However, the pump that is being returned to be exchanged MUST apply to the following conditions: 1) The returning pump needs to be in Brand New condition, Never installed, and CANNOT have any scratches. 2) The ...
  3. 623. Support: Location of Topside cable connection for the VS-Series Controllers Topside Cable Connection for the VS Series Controllers Connect the topside cable plug into J1 connector on the circuit board. The clip on the topside cable plug should snap in place to ensure a secure connection. The J2 connector is for a secondary topside panel, which can be purchased ...
  4. 629. Support: Flow Switch Installation for the CS-Series and M-Series Controllers with Lo-Flow Heaters. Flow Switch Installation Instructions for the CS Series and M Series Controllers with Low Flow Heaters. 1) Flow Switch Appearance: The Flow Switch for Low-Flo Systems is clear blue in color, and will look like a Tee Shape with barb fittings on each end, and with a cable coming out from the ...
  5. 644. Reason for a topside overlay to crack and falling apart (peel away) Cracks, broken or peeling topside overlays are normally caused by allowing the topside panel to be exposed to sun light for many long periods of time. Long periods of sun light exposure will cause the overlay to dry up, crack and peeling off. To avoid future damages to the topside overlay, cover ...
  6. 650. Support: Baptistry or Baptismal Heater Unit Heater ON light is not activating. You have reported that the heater unit is not activating the heater, and the heater ON light does not come on. 1) Verify to make sure correct power is supplied to the heater unit. 2) Make sure the pump is discharging water through the heater with strong water flow. A pressure switch is ...
  7. 656. Support: Dashes displaying on the topside panel for a SD6600-720 LX-15 Sundance Board Dashes on the topside display is a watchdog error code, and is usually caused by bad sensors. If you continue to have this problem, the recommendation would be to replace the temperature and hi-limit sensors.
  8. 658. Support: Now nothing works off the VS-Series Electronic Controller. No display, and no functions from any components You have reported that now nothing works off the VS Series Electronic Controller. No display, and no functions from any components. - Sometimes, there may be a power surge at your location. Make sure all breakers and GFCI's are turned off and turned back on. Then verify that there is either ...
  9. 661. Support: Wiring information on the (15-350-2170) 48-Frame 2.0HP 220V CD WaterWay Pump, 342102A-15. Note that All pumps we sell have the wiring diagram on the motor. If you missed it, here is the wiring information for the (15-350-2170) 48-Frame 2.0 HP, 220V, Center Discharge, WaterWay pump, 342102A-15. Motor S/N: 24012J2, Model number 7-196012-03 (Customer to verify. If different, ...
  10. 662. Support: Wiring information for the (15-350-2150) 48-Frame 1.5HP 220V 1.5" CD Waterway Pump 342062A-15. Note that All pumps we sell have the wiring diagram on the motor. If you missed it, here is the wiring information for the (15-350-2150) 48-Frame 1.5 HP, 220V, 1.5", Center Discharge, Waterway Pump, 342062A-15. Motor Model number F48AD44A79 (Customer to verify. If different, provide correct ...